焦爐煤氣流量計故障檢修的步驟與順序
對于一臺有故障的焦爐煤氣(qi)流(liu)量計,檢修步(bu)驟大體上(shang)可分為命名、縮小(xiao)、確定、查找、維修、試機六大步(bu)。
(1)命名
命名(ming)就(jiu)是(shi)給故(gu)障(zhang)現(xian)(xian)象(xiang)(xiang)起(qi)個(ge)專業的(de)(de)(de)名(ming)稱。當(dang)接到一臺待修的(de)(de)(de)焦(jiao)爐煤氣(qi)流量(liang)(liang)計時(shi),首先(xian)要通(tong)過(guo)使(shi)(shi)(shi)用者了解(jie)情況,細心詢問故(gu)障(zhang)現(xian)(xian)象(xiang)(xiang)、發生的(de)(de)(de)時(shi)間、使(shi)(shi)(shi)用的(de)(de)(de)環境、出現(xian)(xian)的(de)(de)(de)頻繁(fan)次(ci)數及(ji)是(shi)否修過(guo)等。暫時(shi)給故(gu)障(zhang)現(xian)(xian)象(xiang)(xiang) 起(qi)個(ge)“乳名(ming)”。其次(ci)再進行實(shi)際觀(guan)察(cha),應遵循先(xian)外而(er)(er)后(hou)內,先(xian)不通(tong)電(dian)(dian)而(er)(er)后(hou)通(tong)電(dian)(dian)的(de)(de)(de)原則,觀(guan)察(cha)各種操作(zuo)按鍵(jian)、開關、指示燈(deng)、電(dian)(dian)源線等,而(er)(er)后(hou)再拆機查看焦(jiao)爐煤氣(qi)流量(liang)(liang)計內部。最后(hou)通(tong)電(dian)(dian)(在(zai)確認無短路(lu)的(de)(de)(de)情況下(xia))觀(guan)察(cha)是(shi)否是(shi)使(shi)(shi)(shi)用者所描(miao)述的(de)(de)(de)故(gu)障(zhang)現(xian)(xian)象(xiang)(xiang)。去偽(wei)存真,就(jiu)是(shi)說防止使(shi)(shi)(shi)用者因(yin)操作(zuo)不當(dang)而(er)(er)造成的(de)(de)(de)假象(xiang)(xiang),確認故(gu)障(zhang)現(xian)(xian)象(xiang)(xiang)后(hou),確切地給故(gu)障(zhang)起(qi)“真名(ming)”。如引壓管泄(xie)漏(lou)、探(tan)頭堵(du)塞等。這(zhe)樣(yang)便于后(hou)面維修、查找(zhao)有關資料(liao)及(ji)疑難故(gu)障(zhang)時(shi)同行之間的(de)(de)(de)交(jiao)流。
(2)縮小
縮(suo)小就是(shi)把故(gu)障發生(sheng)的范圍(wei)(wei)縮(suo)小到某(mou)個線路板(ban),甚至(zhi)某(mou)個單元(yuan)器(qi)件。通過(guo)對故(gu)障現象的細(xi)心(xin)觀察,下一(yi)步應進入思考分析階段,認真地(di)研究故(gu)障機(ji)的整體(ti)結構和工作原理,焦爐煤氣流量計各部(bu)分之間是(shi)彼此聯系(xi)、互(hu)相影響的,一(yi)種(zhong)故(gu)障現象可能有多(duo)種(zhong)原因(yin),而一(yi)種(zhong)原因(yin)也可能引(yin)起(qi)多(duo)種(zhong)故(gu)障。因(yin)此,在(zai)故(gu)障檢修時,對局部(bu)因(yin)素(su)需進行綜合(he)比較分析,從(cong)而較準確地(di)確定故(gu)障的性質(zhi)與部(bu)位,大致(zhi)判斷(duan)出故(gu)障的范圍(wei)(wei)。如(ru)強制通電后(hou)無任何反應,則可判斷(duan)為儀器(qi)表頭內部(bu)電路故(gu)障。
(3)確定
確定即確定故(gu)障部位。只有熟悉焦爐煤氣流量(liang)計的(de)(de)結構、工作原理、系統性能(neng)及注意事(shi)項,才能(neng)正(zheng)確判(pan)斷其(qi)故(gu)障產生(sheng)的(de)(de)原因,采(cai)取適當(dang)措(cuo)施進(jin)行(xing)排除(chu)處理。上(shang)述(shu)的(de)(de)兩個步驟(zou)基本上(shang)是(shi)分析(xi)而來的(de)(de),當(dang)判(pan)斷出故(gu)障的(de)(de)范圍后,接(jie)下(xia)來需要動(dong)手檢(jian)查,檢(jian)查方(fang)法除(chu)了直(zhi)觀(guan)觀(guan)察法外必須(xu)借助各種儀表(biao)、儀器對故(gu)障部位進(jin)行(xing)確定。測量(liang)、判(pan)斷、分析(xi),如此反復(fu)循環進(jin)行(xing),通過檢(jian)測進(jin)一步縮小故(gu)障范圍,確定故(gu)障部位。
如引(yin)(yin)壓(ya)(ya)(ya)(ya)管泄漏(lou)或探(tan)頭(tou)堵(du)塞,會引(yin)(yin)起(qi)引(yin)(yin)壓(ya)(ya)(ya)(ya)管泄漏(lou)異常,會造(zao)成(cheng)計量有偏(pian)差、不準(zhun),使高壓(ya)(ya)(ya)(ya)和低(di)壓(ya)(ya)(ya)(ya)壓(ya)(ya)(ya)(ya)力下(xia)降(jiang)(jiang);而(er)探(tan)頭(tou)堵(du)塞發(fa)生在(zai)高壓(ya)(ya)(ya)(ya)部分時,會引(yin)(yin)起(qi)高壓(ya)(ya)(ya)(ya)升高、低(di)壓(ya)(ya)(ya)(ya)降(jiang)(jiang)低(di)現象。因此(ci)可以(yi)根據故障現象加以(yi)分析判(pan)斷(duan),從而(er)找到故障部位(wei)。
(4)査找
查找(zhao)(zhao)即查找(zhao)(zhao)故障(zhang)(zhang)線(xian)路(lu)板。當故障(zhang)(zhang)部位縮小到某(mou)一(yi)個(ge)線(xian)路(lu)板或某(mou)一(yi)單元元器(qi)件時,應(ying)進一(yi)步(bu)查找(zhao)(zhao)故障(zhang)(zhang)線(xian)路(lu)板。使得一(yi)次源的(de)測量精(jing)度、重復性(xing)、可靠性(xing)達到一(yi)定(ding)高(gao)度, 應(ying)清楚。通過(guo)學習各種方法的(de)測量、替換等(deng)方式,查找(zhao)(zhao)出故障(zhang)(zhang)線(xian)路(lu)板。
(5)維修
就是維(wei)修流(liu)量計,把流(liu)量計拆開之后,應先排查出故障并(bing)時(shi)行修理或(huo)更換它。對于可修復(fu)的傳感器,應先修復(fu)處理,不能(neng)修復(fu)的傳感器采用(yong)更換。更換傳感時(shi)最好采用(yong)原(yuan)(yuan)型(xing)號(hao),若(ruo)沒有原(yuan)(yuan)型(xing)號(hao)時(shi),就要(yao)考慮(lv)參數和規格相近(jin)的代(dai)(dai)換替代(dai)(dai)。
(6)試機
試(shi)機(ji)就(jiu)是修(xiu)復后(hou),不要急于把焦爐煤氣(qi)流量(liang)計交(jiao)付用戶使用,應(ying)通電試(shi)運(yun)行。經過一段(duan)適當時間的(de)(de)(de)試(shi)機(ji)工作,再復查一體化流量(liang)計修(xiu)復的(de)(de)(de)部位及整機(ji)性(xing)(xing)能,防止(zhi)所(suo)替換的(de)(de)(de)傳感器和“帶(dai)病(bing)傷”的(de)(de)(de)隱(yin)敝(bi)件(jian)的(de)(de)(de)傳感器有質量(liang)問題,使故障沒有達(da)到徹底性(xing)(xing)的(de)(de)(de)排除(chu)。
最新資訊文章
- 流速式流量計的安裝注意也需要一定講究
- 氣體渦街流量計在測量蒸汽爐煤氣時出現問題及解決方法
- 孔板流量計測量瓦斯抽放流量時的安裝要求及取壓方式
- 測蒸汽時應選孔板流量計還是渦街流量計?
- 差壓孔板流量計出現故障時 不妨試試以下方法
- 天然氣流量計管道調試故障原因分析
- 插入式流量計的原理與分類
- 如何消除污水流量計工頻干擾和零點漂移
- 孔板流量計:自動化設計廢鋼鐵行業轉行井噴
- 前后直管段太短時孔板流量計應該如何安裝
- 德爾塔巴流量計的安裝要求以及注意
- 高壓孔板流量計在冷凍水檢測中的注意要點及解決方案介紹
- 選型蒸汽流量計時所需要注意的問題介紹
- 導致孔板流量計誤差變大的原因分析
- 孔板流量計測量蒸汽產生誤差的原因分析及解決辦法
- 深入探究影響孔板流量計進行煤氣流量計量的因素
- 質量流量計和控制器引擎蓋下的主要組件詳細介紹
- 淺析階躍溫度及水流速度對金屬管浮子流量計的影響
- 選擇流量計時會犯的10個常見錯誤以及如何避免錯誤
- 運用標準計量器具校正金屬管浮子流量計
- 壓力變送器接線方式
- 變送器精度標準介紹
- 標準孔板流量計的應用
- 壓力變送器常見故障及處理方法
- 空氣流量計使用故障實例